CH400V-XY Heating Cooling Stage with -190°C to 400°C Range, ±0.1°C Stability and XY ±6mm Precision for Microscopy
GoGo CH400V-XY High-Precision Heating Cooling Stage with XY Sample Manipulation (-190°C to 400°C) The GoGo CH400V-XY is a state-of-the-art Heating Cooling Stage engineered for advanced in-situ microscopy and spectroscopy
- Name: Thermal Stage
- Cooling/Heating Method: Liquid Nitrogen Cooling,Resistance Heating
- Temperature Range: -190℃~400℃
- Temperature Stability: ±0.1℃
- Heating/Cooling Rate: Maximum Heating Rate:150℃/min,Maximum Cooling Rate:40℃/min
- Sample Holder: Silver ;23mm*23mm
技术参数
| 参数 | 规格 / 典型值 |
|---|---|
| Product Details | |
| Place of Origin | Suzhou, China |
| Brand Name | GoGo |
| Certification | ISO 9001:2015 / ISO 14001:2015 / ISO 45001:2018 |
| Model Number | CH400V-XY |
| Payment & Shipping Terms | |
| Minimum Order Quantity | 1 |
| Packaging Details | Cardboard box + wooden box |
| Delivery Time | 30~60 work days |
| Payment Terms | T/T |
| Supply Ability | 1set/day |
| Detail Information | |
| Name | Thermal Stage |
| Cooling/Heating Method | Liquid Nitrogen Cooling,Resistance Heating |
| Temperature Range | -190℃~400℃ |
| Temperature Stability | ±0.1℃ |
| Heating/Cooling Rate | Maximum Heating Rate:150℃/min,Maximum Cooling Rate:40℃/min |
| Sample Holder | Silver ;23mm*23mm |
| Optical Path | Reflection / Transmission(φ2mm Optical Access Hole) |
| Top Window Size | φ20mm*0.3mm/φ25mm*1mm |
| Bottom Window Size | φ10mm*1mm(Transmitted Light Option) |
| Window Material | JGS2 Fused Silica Glass (Transmission Range: 220 Nm - 2500 Nm), Manually Removable And Replaceable. |
| Window Defrosting | Gas Purge Attachment,Air Blowing Defrosting At Low Temperatures |
| Distance From Window Upper Surface To Sample Holder Upper Surface | 5.1mm |
| Chamber Height | 4.8mm |
| Chamber | Vacuum |
| Sample Displacement | X/Y-axis Travel Range: ±6mm, Positioning Accuracy: 0.01mm |
| Microscope Slide | φ16mm*0.15mm |
| Dimensions | 86mm*100mm*21.5mm |
| Net Weight | 0.7kg/0.8kg |
| Basic Configuration | TNEX*1、Optical Heating And Cooling Stage*1、 Temperature Controller*1、Cooling Controller*1、Liquid Nitrogen Tank*1、Recirculating Chiller*1、Cables、Tubing、and Accessories |
| Optional | Adapter Plate/Customized Liquid Nitrogen Tank/Customized Recirculating Chiller/Vacuum System/Computer Host/ Customed Temperature Control Software |
| Highlight | Heating Cooling Stage with -190°C to 400°C range , Precision Heating Cooling Stage for microscopy , Heating Cooling Stage with ±0.1°C stability |
GoGo CH400V-XY High-Precision Heating Cooling Stage with XY Sample Manipulation (-190°C to 400°C)
The GoGo CH400V-XY is a state-of-the-art Heating Cooling Stage engineered for advanced in-situ microscopy and spectroscopy under precisely controlled thermal conditions. Offering an exceptional temperature range from -190°C to 400°C with remarkable stability of ±0.1°C, this system is designed to meet the most demanding requirements of materials science, semiconductor research, and geological sciences.
What sets the CH400V-XY apart is its integrated XY sample manipulation capability. With ±6mm travel range and 0.01mm positioning accuracy, researchers can precisely reposition specific sample regions under the microscope without disturbing the thermal environment—a critical feature for mapping heterogeneous samples or analyzing multiple inclusion sites in a single experiment.
Key Advantages & Why Choose Our Heating Cooling Stage
Extreme Temperature Range with Unmatched Stability: From deep cryogenic -190°C to elevated 400°C, this Heating Cooling Stage maintains ±0.1°C stability, enabling comprehensive study of materials across the full spectrum of operational conditions.
Precision XY Sample Manipulation: The integrated XY translation stage ( ±6mm travel, 0.01mm accuracy) allows detailed spatial mapping and multi-point analysis on a single sample at any temperature—a feature particularly valuable for geological fluid inclusion studies where multiple inclusions must be analyzed within the same thin section.
Dual Optical Paths for Maximum Versatility: Featuring both reflection and transmission optical paths (φ2mm access hole) with high-quality JGS2 fused silica windows (220-2500 nm transmission range), this Heating Cooling Stage supports a wide range of microscopy and spectroscopy techniques.
Vacuum & Atmosphere Control: The sealed chamber supports both vacuum and controlled atmosphere environments, preventing sample oxidation and enabling studies of air-sensitive materials.