

Customized Microscope Heating Stage Versatile Temperature Control Stage For Raman And Optical Analysis
Precision Heating Stage with 600°C Temperature Range, ±0.1°C Stability, and 50°C/min Heating Rate for Microscope and Raman Analysis Product Title: GoGo H800SV Precision Heating Stage for Microscope & Raman Analysis (800°
- Name: Microscope Heating Stage
- Cooling/Heating Method: Resistance Heating
- Temperature Range: RT~800℃
- Temperature Stability: ±0.1℃
- Heating/Cooling Rate: Maximum Heating Rate:50℃/min,Controllable Cooling Rate
- Sample Holde: Stainless Steel;23mm*23mm
技术参数
| 参数 | 规格 / 典型值 |
|---|---|
| Product Details | |
| Place of Origin | Suzhou, China |
| Brand Name | GoGo |
| Certification | ISO 9001:2015 / ISO 14001:2015 / ISO 45001:2018 |
| Model Number | H800SV |
| Payment & Shipping Terms | |
| Minimum Order Quantity | 1 |
| Packaging Details | Cardboard box + wooden box |
| Delivery Time | 30~60 work days |
| Payment Terms | T/T |
| Supply Ability | 1set/day |
| Detail Information | |
| Name | Microscope Heating Stage |
| Cooling/Heating Method | Resistance Heating |
| Temperature Range | RT~800℃ |
| Temperature Stability | ±0.1℃ |
| Heating/Cooling Rate | Maximum Heating Rate:50℃/min,Controllable Cooling Rate |
| Sample Holde | Stainless Steel;23mm*23mm |
| Optical Path | Reflection / Transmission(φ2mm Optical Access Hole) |
| Top Window Size | φ25mm*1mm |
| Window Material | JGS2 Fused Silica Glass (Transmission Range: 220 Nm - 2500 Nm), Manually Removable And Replaceable. |
| Distance From Window Upper Surface To Sample Holder Upper Surface | 4.5mm |
| Chamber Height | 3.5mm |
| Chamber | Atmosphere |
| Dimensions | 91mm*97mm*24mm |
| Net Weight | 0.4kg |
| Basic Configuration | TNEX*1、Optical Heating Stage*1、 Temperature Controller*1、Recirculating Chiller*1、Cables、Tubing、and Accessories |
| Optional | Adapter Plate/Customized Recirculating Chiller/Computer Host/ Customed Temperature Control Software |
| Highlight | Customized Microscope Heating Stage , Versatile Temperature Control Stage , Temperature Control Stage Customized |
Precision Heating Stage with 600°C Temperature Range, ±0.1°C Stability, and 50°C/min Heating Rate for Microscope and Raman Analysis
Product Title: GoGo H800SV Precision Heating Stage for Microscope & Raman Analysis (800°C)
The GoGo H800SV is a versatile and compact Microscope Heating Stage engineered for precise thermal analysis in materials science and life sciences. Offering a temperature range from ambient to 600°C with exceptional stability of ±0.1°C, this stage enables high-quality in-situ microscope observation and Raman spectroscopy. Its innovative silver sample holder ensures excellent thermal conductivity and uniformity. Designed for both reflection and transmission optical paths—the latter via a dedicated φ2mm access hole—the H800SV provides researchers with flexible imaging modalities for studying thin films, polymers, biological samples, and nanomaterials under controlled thermal conditions.
Superior Thermal Precision: Experience highly accurate and stable temperature control with ±0.1°C stability, essential for sensitive experiments and reproducible results in quantitative analysis.
Optimized for Raman & Optical Clarity: The combination of a high-transmission JGS2 silica window and a dual optical path design makes this Microscope Heating Stage particularly effective for Raman spectroscopy and high-resolution optical imaging, minimizing background interference.
Efficient Thermal Performance: Features a rapid heating rate of 50°C/min and integrated active cooling via a recirculating chiller, enabling efficient thermal cycling and protecting sample integrity.
Compact & User-Friendly Design: With a lightweight (0.4kg) and low-profile build (chamber height: 3.5mm), this stage is easily integrated onto most microscope platforms without compromising stage travel or optical working distance.
Intelligent Software Integration: The included TNEX software platform provides seamless computer control for programming complex temperature profiles, automating experiments, and synchronizing data acquisition from multiple instruments.


